Other Tests

 

Vibrations and Shocks CUBIC´s modular system has been vibration and shock tested in standard version with electrical components. The vibration test was carried out by the Danish Army Material Command. Influence 2 G in the frequency range 10-500 Hz in all three planes according to IEC 60068-2-6. The shock test was carried out by Elektronikcentralen. Influence three shocks of 30 G for 12.5 ms in six directions.
Verified by:
The Danish Army Technical Service to IEC 60068-2-6.
Elektronikcentralen to the demands of the Royal Danish Navy,
Det Norske Veritas to own requirements,
Germanischer Lloyd to own requirements, and
Russian Maritime Register of Shipping

Seismic test, earthquake simulation
The CUBIC modular system has fulfilled an earthquake simulation test according to the IEC 60068-2-57 Test Ff: Vibration - Time-history method. As Required Response Spectra, RRS:a, the spectra given in Annexes B and D of the document HN20-E-53 2ème edition Octobre 1994 were used. The earthquake simulation tests were done with biaxial horizontal and vertical multi frequency motions. The ZPA-level at the SSE test was 1 G in the horizontal directions and 0.8 G in the vertical.
Verified by:
Sveriges Provnings- och Forskningsinstitut to IEC 60068-2-57, and
Russian Maritime Register of Shipping

Arcing test
To assess the CUBIC Modular System´s resistance regarding arc faults a number of tests have been carried through. All tests fulfil the six assessment criterions to "Type B assembly" according to SEK 405 and the five criterions according to IEC 61641.
Also tested in accordance to AS/NZS 3439.1 (Australian / New Zealand standard
Verified by:
Kungliga Tekniska Högskolen, Sweden, to IEC/SC-SE 61-141, IEC draft, SEK 405 (Svenska Elektriska Kommissionen, Handbok 405),
Det Norske Veritas to own requirements,
Germanischer Lloyd to own requirements, and
Russian Maritime Register of Shipping.

Surface treatment
CUBIC's Modular System is surface treated with powder lacquer to a thickness of approximately 60-80 my. Teknos Laboratory has carried out a tropical test ISO 6270: Constant climate, air temperature 40 +/- 2 deg. C, 100% relative humidity for 240 hours with excellent results. The Teknos Laboratory concludes that the corrosion resistance is equal to class C2 high according to international standard ISO 12944.
Verified by:
Teknos Laboratory to ISO 6270, ISO 4628-2-5, ISO 2409 and ISO 12944.
Det Norske Veritas to own requirements and
Germanischer Lloyd to own requirements.
Russian Maritime Register of Shipping.