| Vibrations and Shocks |
| CUBIC´s modular system has been vibration and shock tested in standard version with electrical components. The vibration test was carried out by the Danish Army Material Command. Influence 2 G in the frequency range 10-500 Hz in all three planes according to IEC 60068-2-6. The shock test was carried out by Elektronikcentralen. Influence three shocks of 30 G for 12.5 ms in six directions. |
| Verified by: |
| The Danish Army Technical Service to IEC 60068-2-6. Elektronikcentralen to the demands of the Royal Danish Navy, Det Norske Veritas to own requirements, Germanischer Lloyd to own requirements, and Russian Maritime Register of Shipping |
| Seismic test, earthquake simulation |
|
The CUBIC modular system has fulfilled an earthquake simulation test according to the IEC 60068-2-57 Test Ff: Vibration - Time-history method. As Required Response Spectra, RRS:a, the spectra given in Annexes B and D of the document HN20-E-53 2ème edition Octobre 1994 were used. The earthquake simulation tests were done with biaxial horizontal and vertical multi frequency motions. The ZPA-level at the SSE test was 1 G in the horizontal directions and 0.8 G in the vertical. |
| Verified by: |
|
Sveriges Provnings- och Forskningsinstitut to IEC 60068-2-57, and |
| Arcing test |
|
To assess the CUBIC Modular System´s resistance regarding arc faults a number of tests have been carried through. All tests fulfil the six assessment criterions to "Type B assembly" according to SEK 405 and the five criterions according to IEC 61641. Also tested in accordance to AS/NZS 3439.1 (Australian / New Zealand standard |
| Verified by: |
| Kungliga Tekniska Högskolen, Sweden, to IEC/SC-SE 61-141, IEC draft, SEK 405 (Svenska Elektriska Kommissionen, Handbok 405), Det Norske Veritas to own requirements, Germanischer Lloyd to own requirements, and Russian Maritime Register of Shipping. |
| Surface treatment |
| CUBIC's Modular System is surface treated with powder lacquer to a thickness of approximately 60-80 my. Teknos Laboratory has carried out a tropical test ISO 6270: Constant climate, air temperature 40 +/- 2 deg. C, 100% relative humidity for 240 hours with excellent results. The Teknos Laboratory concludes that the corrosion resistance is equal to class C2 high according to international standard ISO 12944. |
| Verified by: |
|
Teknos Laboratory to ISO 6270, ISO 4628-2-5, ISO 2409 and ISO 12944. |